Distal radial and ulnar fractures in miniature- and toy-breed dogs are associated with high rates of delayed union, non-union, and refracture. This retrospective observational study evaluated the outcomes of simple distal radial and ulnar fractures treated by open reduction and internal fixation using a locking plate in a non-rigid configuration.
Ten fractures in eight dogs weighing less than 5 kg were included. Cases were selected according to predefined biomechanical construct criteria, including a plate bridge ratio > 0.7, plate span ratio > 10, plate working length > 40% of the plate length, and screw density < 0.6. The median radiographic follow-up was 224 days (range, 46-408 days).
Radiographic bone healing was achieved in all cases, with a mean time to union of 53 days (range, 28-113 days), and healing occurred faster in skeletally immature dogs. Indirect bone healing with callus formation was observed in 7 of 10 fractures. Minor postoperative complications occurred in three cases and resolved with local treatment. No implant failures or refractures associated with previous screw holes were observed. A reduction in ulnar thickness was identified in evaluable cases, although this finding remained stable during follow-up and did not appear clinically relevant.
These findings suggest that locking plate fixation in a non-rigid configuration provides reliable bone healing with a low complication rate in simple distal radial and ulnar fractures of miniature- and toy-breed dogs.