Thu 9 February 2012
listen this page

Use of Computed Tomography in Standing Position to Identify Guidelines for Screw Insertion in the Distal Phalanx of Horses: An Ex Vivo Study

  • warning: simplexml_load_file() [function.simplexml-load-file]: http://www.orthovetsupersite.org/xml_ev/xml_libriev_42.xml:1: parser error : Document is empty in /home/orthovet/public_html/includes/common.inc(1352) : eval()'d code on line 3.
  • warning: simplexml_load_file() [function.simplexml-load-file]: in /home/orthovet/public_html/includes/common.inc(1352) : eval()'d code on line 3.
  • warning: simplexml_load_file() [function.simplexml-load-file]: ^ in /home/orthovet/public_html/includes/common.inc(1352) : eval()'d code on line 3.
  • warning: simplexml_load_file() [function.simplexml-load-file]: http://www.orthovetsupersite.org/xml_ev/xml_libriev_42.xml:1: parser error : Start tag expected, '<' not found in /home/orthovet/public_html/includes/common.inc(1352) : eval()'d code on line 3.
  • warning: simplexml_load_file() [function.simplexml-load-file]: in /home/orthovet/public_html/includes/common.inc(1352) : eval()'d code on line 3.
  • warning: simplexml_load_file() [function.simplexml-load-file]: ^ in /home/orthovet/public_html/includes/common.inc(1352) : eval()'d code on line 3.
  • warning: Invalid argument supplied for foreach() in /home/orthovet/public_html/includes/common.inc(1352) : eval()'d code on line 5.
  • warning: shuffle() expects parameter 1 to be array, null given in /home/orthovet/public_html/includes/common.inc(1352) : eval()'d code on line 21.
JEAN-MICHEL E. VANDEWEERD, DVM, DES, Cert ES (Soft Tissue) , ROLAND PERRIN, DVM, Diplomate ECVS , THOMAS LAUNOIS, DVM, Diplomate ECVS , LAURENT BROGNIEZ, DVM, SIMON GEHIN, DVM , PETER D. CLEGG, MA, VetMB, Cert EO, Diplomate ECVS, MRCVS et al. Veterinary Surgery April 2009 38 3 373 - 379
ABSTRACT Objectives—To compare the precision of radiography and computed tomography (CT) preoperatively in the standing position for identification of guidelines for screw insertion in the distal phalanx, and to identify whether standing CT might improve operative time compared with preoperative radiographic planning. Study Design—Experimental ex vivo study. Animals—Cadaveric equine thoracic limb pairs (n=10). Methods—Insertion of a 4.5 mm cortex screw in lag fashion into an intact distal phalanx was evaluated in 2 groups (n=10) of cadaveric equine thoracic limbs. In 1 group, the site, direction, and length of the implant were determined by radiography, and in the other group, by CT. Accuracy of screw placement was verified by specimen dissection. Outcomes were (1) absence of penetration of the articular surface, the solar surface, or the semilunar canal (2) appropriate length and direction of the screw. Surgical time was also measured. Results—No screw penetrated the articular surface, the solar surface, or the semilunar canal in either group. CT was more accurate to identify guidelines for screw insertion (U=23.50, P=.049). With CT, surgical time (mean, 7.7 minutes) was significantly shorter (U=0.000, P=.000) than with radiography (mean, 12.7 minutes). Conclusion—Standing CT can be used to accurately determine anatomic landmarks for screw insertion in lag fashion in sagittal fractures of the distal phalanx. Clinical Relevance—This study has a clear clinical relevance for improved internal fixation of sagittal fractures of the distal phalanx.

Official newsletter

Stay informed with OrthoVetSuperSite Newsletter

Small Animals Poll Large Animals Poll

Vet Events

Events

« February 2012
SunMonTueWedThuFriSat
1234
567891011
12131415161718
19202122232425
26272829